According to plumbing code drain pipe has to be sloped a minimum of 1 4 inch per foot and a maximum of three inches per foot or vertical.
Slope to drain 1 2 foot roof.
For example multiplying 12 inches by 2 percent or 0 02 equals 0 24 which represents a slope of roughly 1 4 inch per 12 inches.
The minimum pitch for a roof is 1 4 12 which translates to 1 4 inch rise to 12 inches of run.
In these instances a system of drains or gutters is necessary to channel the water away from the roof.
Tips on calculating drain pipe slopes.
The slope of a roof or pitch is determined by how many inches the roof rises over 1 foot or 12 inches.
The recommended slope is 1 4 inch per foot but it can be anywhere from 1 8 inch to 3 8 inch per foot depending on other factors.
A length to width ratio of 2 to 1 can maximize water flow especially when deck slope is 1 4 inch per foot 2.
The 1 2 inch per foot slope is used as it doubles the slope of the structurally sloped roof deck which in this case has a slope of 1 4 inch per foot.
The sand should be sloped away from the house at the rate of one inch per 20 feet.
Calculating the slope of your drain pipe is easy.
Level roof decks with tapered insulation whether re roofing or new construction getting the drainage correct on level roof decks is still a challenge for most designers.
A slope of less than 1 4 inch per foot will cause constant drain clogs and a slope of more than three inches will allow the water to drain without the solids.
Commercial buildings with a slope like this are considered low slope.
Use the longest level possible for your application for the best accuracy.
Quicket can be installed between two layers of roof insulation or placed under an approved cover board.
However you can only use this pitch with built up roofing or specialized synthetic roofing.
Common roof pitches and equivalent grade degree and radian angles.
Drains are usually located at the low points or valleys of the roof.
Alternatively builders and codes might simply express the code as 1 4 inch per foot this is the case for drain pipe diameters of 2 1 2 inch or less according to the international plumbing code.
Same logic with 1 8 slope 1 16 slope etc.
This means that the rise of the slope goes up or down 8 inches for every 12 inches.
This means that for every foot of the roof it must slope downward by at least one quarter inch.
A pitch over 9 12 is considered a steep slope roof between 2 12 and 4 12 is considered a low slope roof and less than 2 12 is considered a flat roof.
To put it in perspective the angle of this slope would be around 30 degrees.
Quicket is engineered to elevate the membrane surface as the distance increases away from the roof drains and scuppers.
When the bubble on a level is about 1 4 of the way past the line it is about a 1 4 slope.
Most roof s have a pitch in the 4 12 to 9 12 range.